SYNTHETIC SEALING MEMBRANE FOR BRUSH AND SPRAY APPLICATION

FLUID MEMBRANE

FLUID MEMBRANE is the synthetic waterproofing membrane that can be applied by roller, brush or spray.

It is resistant to water stagnation on the surface even when there is no slope, and is perfect for surfaces in industrial areas or sea areas.

Videos

FLUID MEMBRANE WATERPROOFING MEMBRANE: PERFECT ADHESION, SUPERIOR DURABILITY.

The FLUID MEMBRANE fluid membrane offers also the possibility of inserting a synthetic reinforcement fabric.
The synthetic resin mix is elastic and resistant to any movement of the sealed cracks.

Thanks to its formulation, it offers perfect adhesion; is suitable for complex construction details and resists micro-cracks.
Odourless, non-toxic and solvent-free product.

Documents

Technical data sheets
Declaration of performance (DOP) Download
Fluid Membrane Coverage Spreadsheet

FLUID MEMBRANE

CODE content
[kg]
pcs.
FLUIDMEM 10 1

Technical Data
EN 1504-2 EN 14891

Property Standard Tested Values USC Conversion
Classification (1) EN 14891 DM O1 -
Classification (2) EN 1504-2 C PI-MC-IR -
Colour - grey -
Density at +20 °C ISO 2811-1 1,45 kg/L 232.52 oz/gal
Material yield per 1 mm thickness - ≥ 1,5 kg/m² -
Surface cross-linking time 23 °C / 50% RH (3) - 4 hours -
Time required for complete drying 23 °C / 50% RH (3) - 24 hours -
Dry residue by mass ISO 3251 65 % -
Dynamic viscosity EN ISO 3219 48 / 72 Pa·s -
Adhesion on concrete by direct traction EN 1542 > 1 N/mm² > 145 lbf/in²
Watertightness EN 14891 conforming -
Liquid water permeability (W) EN 1062-3 < 0,1 kg/(m²·h⁰’⁵) -
Water vapour resistance factor (μ) UNI EN 1931 ca. 9000 -
Water vapour transmission (Sd) (4) EN ISO 7783 1,8 m 1.943 US perm
Carbon dioxide permeability (C) EN 1062-2 > 50 m -
VOC content Dir. 2004/42/CE 0 g/L -
Application temperature - 5 / 35 °C 41 / 95 °F
Storage temperature (5) - ≥ 5 °C ≥ 41 °F
1.
2.
3. The data expressed may vary depending on the thickness of the product applied and the specific installation conditions: temperature, humidity, ventilation, absorbency of the substrate.
4. For a thickness of 200 µm
5.

Specifications

Supply and installation of synthetic sealing membrane for brush and spray application, type FLUID MEMBRANE
CE marking in accordance with: : EN1504-2 EN14891

Properties:

  • Water vapour transmission Sd [m] : < 5
  • Application temperature [°C] : +5/+35
  • Air permeability : no
  • Watertightness [kPa] : conforme

It can be applied on various smooth building substrates such as timber, OSB boards without additional surface treatment. The surfaces must be dry, free of dust and solvents such as grease or oil. We recommend the use of PRIMER for rough surfaces such as rough OSB boards. After the separation film has been partially separated, the tape can be applied easily and precisely at the corner point without further corrections. The sealing is completed by separating the remaining film and adhering the tape to the support. Once the tape has been applied, it is recommended to use the special roller RLL45 to obtain a perfect application.