PLASTER BAND IN and PLASTER BAND OUT are high adhesion tapes ideal for application on most surfaces, even at low temperatures. Made of technical fabric, they can be plastered after installation.
PLASTER BAND IN/OUT: vapour control and airtightness tapes that can be plastered.
PLASTER BAND is available in two versions: PLASTER BAND IN for application inside the envelope, PLASTER BAND OUT for application on the outside of the envelope. Even when applied in tight spaces and corners, the PP liner of these two highly adhesive tapes can be removed without risk of failure.
The pre-cut liner allows for quick and easy installation and an high level of aesthetics due to the possibility of concealing the tape behind claddings or plaster.
CODE | liner | B
[mm]
|
L
[m]
|
liner
[in]
|
B
[in]
|
L
[ft]
|
pcs. |
---|---|---|---|---|---|---|---|
PLASTIN1560 | 15/60 | 75 | 25 | 0.6/2.4 | 3 | 82 | 5 |
PLASTIN1585 | 15/85 | 100 | 25 | 0.6/3.3 | 3.9 | 82 | 4 |
PLASTIN15135 | 15/135 | 150 | 25 | 0.6/5.3 | 5.9 | 82 | 2 |
PLASTIN7520 | 75 | 75 | 25 | 3 | 3 | 82 | 5 |
PLASTIN10020 | 100 | 100 | 25 | 3.9 | 3.9 | 82 | 4 |
PLASTIN15020 | 150 | 150 | 25 | 5.9 | 5.9 | 82 | 2 |
CODE | liner | B
[mm]
|
L
[m]
|
liner
[in]
|
B
[in]
|
L
[ft]
|
pcs. |
---|---|---|---|---|---|---|---|
PLASTOUT1560 | 15/60 | 75 | 25 | 0.6/2.4 | 3 | 82 | 5 |
PLASTOUT1585 | 15/85 | 100 | 25 | 0.6/3.3 | 3.9 | 82 | 4 |
PLASTOUT15135 | 15/135 | 150 | 25 | 0.6/5.3 | 5.9 | 82 | 2 |
PLASTOUT15185 | 15/185 | 200 | 25 | 0.6/7.3 | 7.9 | 82 | 2 |
PLASTOUT7520 | 75 | 75 | 25 | 3 | 3 | 82 | 5 |
PLASTOUT10020 | 100 | 100 | 25 | 3.9 | 3.9 | 82 | 4 |
PLASTOUT15020 | 150 | 150 | 25 | 5.9 | 5.9 | 82 | 2 |
PLASTOUT20020 | 200 | 200 | 25 | 7.9 | 7.9 | 82 | 2 |
Property | Standard | Tested Values | USC Conversion |
---|---|---|---|
Thickness | DIN 53855 | 0,5 mm | 19.7 mil |
Water vapour transmission (Sd) | EN 1931 / EN ISO 12572 | ca. 10 m | ca. 0.35 US perm |
Watertightness | EN 14891 | - | - |
Reaction to fire | EN 13501-1 | class E | - |
Resistance to temperature | - | 40 / 80 °C | 104 / 176 °F |
Application temperature (1 ) | - | > 5 / °C | > 41 / °F |
Storage temperature (2 ) | - | 5 / 25 °C | 41 / 77 °F |
Exposure to weather | - | 3 month | - |
Resistance to heavy rain | EN 1027 | ≥ 1050 Pa | - |
Resistance to penetration of air | EN 12114 | < 0,1 m³/(m²·h·50Pa) | < 0.005 cfm/ft² at 50Pa |
Solvents | - | no | - |
Property | Standard | Tested Values | USC Conversion |
---|---|---|---|
Thickness | EN 1942 | 0,7 mm | 28 mil |
Mass per unit area | EN 1849-2 | 360 g/m² | 1.18 oz/ft² |
Water vapour transmission (Sd) | EN 1931 / EN ISO 12572 | ca. 1 m | ca. 3.497 US perm |
Tensile strength MD/CD | EN 12311-1 | 290 / 190 N/50mm | 33 / 22 lbf/in |
Elongation MD/CD | EN 12311-1 | 75 / 135 % | - |
Watertightness | EN 1928 | class W1 | - |
Resistance to heavy rain | EN 1027 | ≥ 1050 Pa | - |
Resistance to penetration of air | EN 1026 | ≤ 0,1 m³/(h·m·daPa⅔) | - |
UV resistance | - | 12 months | - |
Reaction to fire | EN 13501-1 | class E | - |
Solvents | - | no | - |
Emicode | procedura di prova GEV | EC1 plus | - |
Resistance to temperature | - | 40 / 80 °C | 104 / 176 °F |
Application temperature | - | > -10 °C | > 14 °F |
Storage temperature (1 ) | - | 5 / 25 °C | 41 / 77 °F |
SUPPORT | 2-layer PP vapour control membrane |
---|---|
GLUE | acrylic dispersion without solvents |
RELEASE LINER | easy-release PP film |
SUPPORT | breathable 2-layer PP membrane |
---|---|
GLUE | acrylic dispersion without solvents |
RELEASE LINER | easy-release PP film |