WATERPROOFING MEMBRANE FOR FOUNDATIONS PROTECTED AGAINST TERMITES
TERMI FLOOR
TERMI FLOOR is the waterproofing barrier for foundations protected against termites and other unwanted insects for over 20 years.
The TERMI FLOOR barrier is active on both sides for double effective protection (even in cases of possible complications during installation) and does not present any risk to the environment when installed or danger to humans during installation.
Consisting of a single layer of low-density polyethylene, it is applied to the inside and outside of walls, in contact with the ground.
TERMI FLOOR, THE MEMBRANE THAT SOLVES THE PROBLEM OF TERMITES AT THE BASE
TERMI FLOOR is an active barrier that allows you to eliminate termites without the use of pesticides. It contains a chemical agent that is neither dangerous to humans nor to the environment, which has the function of driving termites away and, in the case of prolonged contact, eliminate them.
The product does not release substances into the soil. Its effectiveness is ensured by contact or inhalation of the substance by insects alone.
Documents
Technical data sheets | |
---|---|
Declaration of performance (DOP) |
TERMI FLOOR
CODE | roll
[m]
|
H
[m]
|
L
[m]
|
A
[m²]
|
H
[ft]
|
L
[ft]
|
A
[sft]
|
pcs./pallet |
---|---|---|---|---|---|---|---|---|
TERMI150 | 1 x 12.5 | 3 | 25 | 75 | 9' 10 1/8'' | 82 | 807 | 48 |
Technical Data
Property | Standard | Tested Values | USC Conversion |
---|---|---|---|
Mass per unit area | EN 1849-2 | 150 g/m² | 0.49 oz/ft² |
Thickness | EN 1849-1 | 0,15 mm | 6 mil |
Water vapour transmission (Sd) | EN 1931 | - | - |
Tensile strength MD/CD | EN 12311-1 | 15 / 15 N/50mm | 2 / 2 lb/in |
Elongation MD/CD | EN 12311-1 | 350 / 450 % | - |
Resistance to nail tearing MD/CD | EN 12310-1 | 40 / 40 N | 9 / 9 lbf |
Watertightness | EN 1928 | compliant | - |
Thermal resistance | - | -40 / 80 °C | -40 / 176 °F |
Reaction to fire | EN 13501-1 | class F | - |
Resistance to penetration of air | EN 12114 | > 0,02 m³/(m²·h·50Pa) | > 0.001 cfm/ft² at 50Pa |
Thermal conductivity (λ) | - | 0,4 W/(m·K) | 2.77 (BTU·in)/(h·ft²·°F) |
Specific heat | - | 1800 J/(kg·K) | - |
Density | - | ca. 1000 kg/m³ | - |
Water vapour resistance factor (μ) | - | - | - |
Impact resistance | EN 12691 | 200 mm | 7.874016 in |
Resistance to static load | - | 5 N | 1.124045 lbf |
Water vapour resistance - in the presence of alkalis | EN 1847 / EN 12311-2 | compliant | - |
Water vapour resistance - after artificial ageing | EN 1296 / EN 1931 | compliant | - |
Specifications
Supply and installation of waterproofing anti-termite barrier for foundations, type TERMI FLOOR
CE marking in accordance with: : EN13967
Composition:
Single layer low density PE film
Properties:
- Thickness [mm] : 0,15
- Temperature resistance [°C] : -40/+80
- Reaction to fire : classe F
- Watertightness [kPa] : conforme
It can be applied on various smooth building substrates such as timber, OSB boards without additional surface treatment. The surfaces must be dry, free of dust and solvents such as grease or oil. We recommend the use of PRIMER for rough surfaces such as rough OSB boards. Once the tape has been applied, it is recommended to use the special roller RLL45 to obtain a perfect application.
Composition
single layer | - |
---|